FTTH installation
Power measurement and optical link verification.

Compact 4-in-1 optical multimeter with -50 to +26 dBm OPM, integrated VFL with an advertised range of up to 5 km, RJ45 wire sequence tester and auxiliary LED light. InGaAs detector, ten calibrated wavelengths and measurement storage.
Compact 4-in-1 optical multimeter with -50 to +26 dBm OPM, integrated VFL with an advertised range of up to 5 km, RJ45 wire sequence tester and auxiliary LED light. InGaAs detector, ten calibrated wavelengths and measurement storage.
Integrates wavelength recognition and modulated signal identification for installation and maintenance work. The RJ45 tester checks wire sequence and continuity up to 300 m. It features a Type-C interface and automatic shutdown after 10, 30 or 60 minutes.

Power measurement and optical link verification.
Visual fault location using VFL.
RJ45 continuity and wire sequence testing up to 300 m.
Measurement storage and auxiliary LED lighting.
Get preferential commercial terms, stock availability and specialist technical advice for your installation.
Download the official datasheet and certified PDF resources for projects and tenders.
Quick answers to help you select and request this product.
This version measures from -50 to +26 dBm. It uses an InGaAs detector and covers an OPM spectral range of 800 to 1700 nm.
Ten: 850, 980, 1270, 1300, 1310, 1490, 1550, 1577, 1625 and 1650 nm.
The datasheet states OPM uncertainty of ±5%, linear resolution of 0.1% and logarithmic resolution of 0.01 dBm.
CW, 270 Hz, 330 Hz, 1 kHz and 2 kHz. It also supports wavelength recognition and measurement storage.
The advertised range is up to 5 km and depends on fiber conditions. It operates at 650 ±30 nm in continuous mode or pulsed at 1 Hz or 2 Hz.
The datasheet offers 2, 10, 30 and 50 mW configurations. The specific power depends on the supplied configuration.
The standard function checks wire sequence and continuity with a range of up to 300 m. Cable tracing is optional. This test does not certify the link's transmission category.
The datasheet specifies three AAA batteries as the standard power supply and a 3.7 V / 700 mAh lithium battery as an option. It has a Type-C interface. The stated nominal runtime is at least 120 hours in OPM mode, depending on configuration and conditions of use.
KONGIA 5-year warranty.
Do not look directly at the VFL emitter or into live fibers. Check the power configuration and equipment adapters before connection.
Our team can help with quotations, availability and technical support for distributors.